Unlock the power of precision analysis with our Full Spectrum Flow Cytometer

Cytek Aurora

A prodigy that’s taking flow cytometry to the next level of performance and flexibility.

 

Cytek Aurora CS

A high-end sorter fueled by Cytek’s innovative full spectrum technology.

Cytek Northern Lights

Full Spectrum Flow Cytometry for all

Cytek® Aurora

A prodigy that’s taking flow cytometry to the next level of performance and flexibility.

So Many Colors

Up to 40 colors demonstrated including fluorochromes with emission spectra in close proximity to each other.

Exceptional Sensitivity

Sensitivity redefined using state of the art optics and low noise electronics.

A New Level of Flexibility

No changing optical filters for any fluorochrome. Use any commercially available fluorochrome excited by the onboard lasers.

Technology

High Level Overview

The Cytek Aurora leverages full spectrum technology to provide unprecedented flexibility to scientists, enabling the use of a wide array of new fluorochrome combinations without reconfiguring the system for each application. The Aurora system delivers high-resolution data at the single-cell level to resolve the most challenging cell populations, such as cells with high autofluorescence or low levels of expression of key biomarkers, regardless of assay complexity.

Aurora Laser system

3 to 5 laser configurations

Light Spectrum

365-829 nm range

State-of-the-art Optics

Flat-top beam profiles

Deep Immunoprofiling

The Cytek Aurora’s use of full spectrum flow cytometry combined with the SpectroFlo® software’s real-time unmixing capability provides greater fluorochrome choice and panel flexibility and allows users to quickly visualize data and statistics. All this results in the ultimate flow cytometry solution for deep immunoprofiling, from 24 colors all the way to 40 colors.

24 Colors

The three-laser configuration provides outstanding multi-parametric data for a wide array of applications. Check out how markers and fluorochromes in a 24-color panel designed for identification of circulating cell subsets in human peripheral blood look when run on the Aurora system.

Violet Excited Dyes Emission Spectra

Blue Excited Dyes Emission Spectra

Red Excited Dyes Emission Spectra

40 Colors

Until recently, developing fluorescence-based flow cytometry assays with 40 colors has been merely aspirational, with many turning to competing technologies for high-parameter applications. No longer. With 64 fluorescence detectors and only 5 lasers, the Cytek Aurora now has the capability to resolve up to 40 colors in combination. Cytek has developed a 40-color human immunophenotyping panel acquired from a single tube, with outstanding resolution.

Cytek® Aurora CS

A high-end sorter fueled by Cytek’s innovative full spectrum technology

Optical Performance

The ability to generate high quality multi-parametric data is key to successfully utilize data dimensionality and 2-D visualization algorithms. Run the OMIP-069 (PMID: 32830910) 40-color deep immunophenotyping panel on the Cytek Aurora system, and sort it on the Cytek Aurora CS with similar performance.

Benefits

Exceptional Sensitivity

Sensitivity redefined using state of the art optics and low noise electronics.

So Many Colors

Up to 40 colors demonstrated including fluorochromes with emission spectra in close proximity to each other.

A New Level of Flexibility

No changing optical filters for any fluorochrome. Use any commercially available fluorochrome excited by the onboard lasers.

Seamless Sorting

Transfer assays with ease, experience automated drop delay, clog detection, sort monitoring, and sort reporting.

Cytek Northern Lights

Full Spectrum Flow Cytometry for All

High Value

Upgradeable from one laser and nine colors to three lasers and 24 colors, there is a Northern Lights configuration to fit your needs

Remarkable Sensitivity

Sensitivity redefined using state-of-the-art optics and low-noise electronics

Easy, Flexible, & Intuitive

One configuration for all assay, use any commercially available fluorochrome, intuitive software

Low Cost of Ownership

Use fewer lasers to run more colors for greater cost savings and less setup time between experiments

High Level Overview

The Cytek Northern Lights is a full spectrum flow cytometer that shifts the paradigm in what scientists expect to see in performance from an affordable one-to-three laser system. Cytek Northern Lights incorporates the same groundbreaking technologies as the Aurora system, allowing for a wide array of new fluorochrome combinations without reconfiguring your system for each application. The Northern Lights, with its easy-to-use workflow is the highly valuable full spectrum flow solution for everyday research applications.

Everyday Immunoprofiling

Full spectrum flow cytometry opens a wide range of new possibilities. The Northern Lights allows scientists to run complex multicolor experiments with as few as one or two lasers. The unique optical system enables the use of dyes with highly overlapping peak emissions without sacrificing resolution, translating to more flexibility in dye choice.

21 Colors

With 30 fluorescence detectors and only 2 lasers (405 and 488 nm), the Cytek® Northern Lights enables multi-parametric data collection with few lasers to maintain. Cytek has developed a 21-color human immunophenotyping panel acquired from just a single tube, with outstanding resolution.

9 Colors

The one laser (488 nm) Cytek® Northern Lights can perform 9-color immunoprofiling assays with no sacrifice to data quality. In this 9-color blue laser excitable dyes panel, monocytes and several CD4 T cell and CD8 T cell subsets were easily identified.

SpectroFlo

A new approach to flow cytometry acquisition software.